Product Description
Mushroom sterilizer adopts PLC system control, automatic air intake, automatic exhaust, side plate bending treatment to increase strength, high temperature silicone inflation seal, safety pressure valve, overpressure protection, can realize automatic control of sterilization.
Advantages of Edible Fungi Sterilization Cabinet
1. Edible mushroom sterilization cabinet can use high temperature to kill bacteria, pathogens and pathogenic bacteria in edible mushrooms, ensuring the hygiene and safety of edible mushrooms.
2. Mushroom products treated with edible mushroom sterilization cabinets can not only sterilize, but also maintain the nutritional content of edible mushrooms, making them taste better and of higher quality.
3. Edible mushroom sterilization cabinets can also extend the shelf life of edible mushrooms and reduce waste by adjusting parameters such as temperature and humidity.
Detailed Photos
Structure of sterilization cabinet:
It consists of the sterilization cabinet body, sealing door, control valve, control panel, insulation jacket, and its matching measurement and control components. Its main function is to kill bacteria in mushrooms under vacuum pumping and continuous high temperature operating conditions.
Product Parameters
Category |
Specifications |
Internal Dimensions |
External Size |
Withstand pressure |
Weight |
Single door |
24.2m3 |
2.2x2.2x5m |
2.5x2.5x5.35m |
20KPa |
3820kg |
Single door |
40.3m3 |
2.2x2.2x8.33m |
2.5x2.5x8.7m |
20KPa |
6568kg |
Double doors |
62 m3 |
2.2x2.2x12.8m |
2.5x2.5x13.2m |
20KPa |
11942kg |
Single door |
38.4m3 |
2.2x2.3x7.6m |
2.5x2.6x7.95m |
20KPa |
8265kg |
Double doors |
61.7m3 |
2.2x2.3x12.2m |
2.5x2.6x12.6m |
20KPa |
10783kg |
Single door |
66.2m3 |
2.2x2.3x13.1m |
2.5x2.6x13.5m |
20KPa |
11480kg |
Double doors |
63.3m3 |
2.2x2.4x12m |
2.5x2.7x12.5m |
20KPa |
10975kg |
Double doors |
63.4m3 |
2.3x2.3x12m |
2.6x2.6x12.5m |
20KPa |
11086kg |
Lift double doors |
65.7m3 |
2.2x2.3x13m |
2.5x2.6x13.6m |
35KPa |
13352kg |
Lift single door |
77.6m3 |
2.28x2.45x13.9m |
2.58x2.75x14.4m |
35KPa |
15279kg |
Product show
Matters Needing Attention |
1. Before use, check whether each component is intact and ensure that the connectivity of each system is normal.
2. Sterilized products require sealed packaging bags with no defects, leaks, deformations, or other issues.
3. During the sterilization process, the internal pressure status should be observed at all times to confirm that the steam level is within the safe range.
4. After sterilization is completed, wait for the sterilization cabinet to cool down before opening the cabinet door.
5. It is strictly prohibited to directly touch sterilized mushroom bags with hands.
6. Regularly remove scale, sediment, etc. from the sterilization cabinet to ensure that the interior is dry and odorless.
7. Regularly check the sealing of the sterilization cabinet door and clean and maintain the sealing ring.
Scope of application:
This device is suitable for sterilization treatment of various mushrooms and fungi, including but not limited to oyster mushroom, Pleurotus geesteranus, Agrocybe cylindracea, etc.
Company Profile